Measured flow to quote input

Assist Gas Consumption Matrix

Convert measured flow and gas-on time into volume while preserving units and reference conditions. The worked matrix explains L/min, m³/h, standard flow, and separate purge/pierce stages. All numbers are arithmetic examples, not cutting settings.

Content reviewed 2026-11-02. Verify the applicability of each source before using a value in a quote.

Input to record

Gas identity, meter flow and unit, actual or reference-state conditions, non-overlapping gas-on stages, and a supplier price on the same volume basis.

Output to carry forward

Volume by stage and total volume on a stated basis, ready for the existing gas calculator and quote cost stack.

Flow × time

For constant measured flow, V = Q × t with matching time units. L/min × minutes gives liters; divide by 1,000 for m³. For changing flow, calculate each measured interval separately and add volumes only on the same reference basis. Include purge and piercing once; exclude idle time when gas is off.

L/min is actual volumetric flow at the stated conditions. Standard L/min refers to a specified reference temperature and absolute pressure. Keep those conditions with the result and match them to the supplier’s billing basis before multiplying by a price. The table does not convert actual flow into standard flow, mass, cylinder capacity, or liquid-gas volume.

Pressure and gas cost

Pressure is a process record, not a flow reading. Record whether it is gauge or absolute and where it was measured. This worksheet does not derive flow from nozzle diameter or regulator pressure. Use a measured meter record, a scoped OEM flow chart, or a supplier measurement method instead.

Variable gas cost = same-basis consumed m³ × your supplier price per m³. Record currency, invoice date, and billing conditions. Keep rental, delivery, tank losses, and generator power/service as separate cost inputs so the quote does not count them twice. Carry the recorded volume assumptions into the gas calculator, then the laser-cutting quote.

Gas usage record

Record your own setup and download a CSV. Fields stay in this page only, are not submitted, and clear on reload. A completed record is not approval of a machine setting.

Sources and scope

Content reviewed 2026-11-02. A documentation reference supports the stated method or data only; it does not approve settings on another machine.

  • Alicat: Mass Flow vs. Volumetric Flow

    Actual volumetric flow varies with pressure and temperature; standardized volumetric flow such as SLPM/NLPM is tied to reference conditions. This source does not supply laser-nozzle flow settings.

  • Alicat: What is Mass Flow?

    Explains reference-state volumetric units and mass-flow relationships. Confirm the meter’s configured reference temperature/absolute pressure; do not assume every supplier or instrument uses one default.

Showing 6 of 6 rows

Assist Gas Consumption Matrix reference rows
Illustrative flowGas-on timeCalculationVolume outputVolume basisPressure contextSource / methodApplicabilityConfidenceReviewed
30 L/min10 min30 × 10 / 10000.300 m³Actual volume at the recorded meter conditionsRecord measurement point and gauge/absolute basis; not used to infer flowUnit arithmetic derived from Q × t; Alicat source supports the distinction between actual and reference-state flowIllustrative flow/time inputs only; not recommended gas settings for any head, gas, material, or thicknessDeterministic unit example; replace inputs with a measured record2026-11-02
30 L/min90 s = 1.5 min30 × (90 / 60) / 10000.045 m³Same actual-state basis as the flow readingSame basis as the flow record; no pressure-to-flow conversionUnit arithmetic derived from Q × t; Alicat source supports the distinction between actual and reference-state flowIllustrative flow/time inputs only; not recommended gas settings for any head, gas, material, or thicknessDeterministic unit example; replace inputs with a measured record2026-11-02
1.8 m³/h10 min = 1/6 h1.8 × 10 / 600.300 m³Retain actual or reference-state basis from the meterLog as separate process contextUnit arithmetic derived from Q × t; Alicat source supports the distinction between actual and reference-state flowIllustrative flow/time inputs only; not recommended gas settings for any head, gas, material, or thicknessDeterministic unit example; replace inputs with a measured record2026-11-02
30 standard L/min10 min30 × 10 / 10000.300 reference m³Use exactly the meter’s specified reference temperature and absolute pressureReference pressure is not the nozzle’s gauge pressureUnit arithmetic derived from Q × t; Alicat source supports the distinction between actual and reference-state flowIllustrative flow/time inputs only; not recommended gas settings for any head, gas, material, or thicknessDeterministic unit example; replace inputs with a measured record2026-11-02
Cut: 30 L/min; purge: 10 L/minCut: 10 min; purge: 2 min(30 × 10 + 10 × 2) / 10000.320 m³Sum only when both readings use the same state basisRecord each stage independentlyUnit arithmetic derived from Q × t; Alicat source supports the distinction between actual and reference-state flowIllustrative flow/time inputs only; not recommended gas settings for any head, gas, material, or thicknessDeterministic unit example; replace inputs with a measured record2026-11-02
12 L/min during gas-on stage20 repeats × 3 s = 1 min12 × (20 × 3 / 60) / 10000.012 m³Count only additional gas-on time not already in cut/purge totalsRecord stage pressure; duration alone is not a flow measurementUnit arithmetic derived from Q × t; Alicat source supports the distinction between actual and reference-state flowIllustrative flow/time inputs only; not recommended gas settings for any head, gas, material, or thicknessDeterministic unit example; replace inputs with a measured record2026-11-02

Reference workflow

  1. Match the job, material, machine head, and quality requirement to a row.
  2. Confirm the source, review date, and confidence before copying the value into a quote worksheet.
  3. Use a measured result or current OEM record when the row is marked as required or unverified.

Related references