Routine-scoped measurement record

Measured Piercing Time

Aggregate actual CAM pierce counts and measured seconds per routine. Keep the head, material, gas, timing boundaries, and reviewer decision with the result instead of selecting a strategy from an unsupported thickness threshold.

Content reviewed 2026-11-02. Verify the applicability of each source before using a value in a quote.

Input to record

Actual event counts by routine, measured seconds/event, CAM revision, machine/head, stock, gas setup, timing source, and approval record.

Output to carry forward

Total pierce seconds and minutes, with a routine-level CSV and the scope needed before using the result in a cycle-time quote.

Measured pierce groups

Group actual CAM events by the exact measured routine. Enter seconds per event, not minutes. The tool adds measured event time; it does not choose a piercing strategy or duplicate the full cycle-time calculator. Inputs stay local and clear on reload.

Measured piercing groups
Routine / revisionEventsSeconds/eventTotal secondsAction
—

Name each routine and enter whole nonnegative event counts. A group with events needs a positive finite measured duration.

Timing boundary

Record whether the timed routine includes preflow, focus movement, pulse/dwell, breakthrough confirmation, and post-delay. Do not add the same controller delay again if the CAM cycle already includes it. Use separate groups when routine duration differs; the tool does not infer these durations from power or thickness.

A notional 20 events × 1.5 seconds plus 10 events × 3 seconds equals 60 seconds, or 1 minute. These are arithmetic inputs only, not recommended piercing times. Feeding, travel, loading, and finishing remain separate stages.

Sources and scope

Content reviewed 2026-11-02. A documentation reference supports the stated method or data only; it does not approve settings on another machine.

Showing 4 of 4 rows

Measured Piercing Time reference rows
RecordCheck / methodOutputBoundarySource / methodApplicabilityConfidenceReviewed
Actual pierce eventsCount programmed pierces by routine in CAM; record restart/re-pierce assumptions separatelyWhole event count for each timed routineDo not infer the count from hole count alone; edge starts and shared paths can change itLaserCalc Pro measured-event accounting methodActual CAM program and revisionProgram review required; no automatic file parsing2026-11-02
Measured seconds per eventRecord which controller stages are inside the measured interval, repetitions, and raw durationMeasured seconds/event for the exact routine, head, stock, and gas setupDo not add delay twice when it is already included in controller/CAM cycle timeLaserCalc Pro measured-event accounting methodRecorded machine, material/lot, thickness, gas, nozzle, and routine revisionTimed shop evidence required2026-11-02
Mixed-routine totalFor each group multiply event count × measured seconds/event; add group secondsTotal seconds / 60 = total minutesPiercing only; excludes feed, travel, loading, and any separately counted gas stageDerived arithmetic, not a machine performance claimNon-overlapping event groups on one jobDeterministic calculation; input confidence depends on measurement2026-11-02
Release and re-testAttach coupon result, source revision, operator, reviewer, and drawing acceptance criteriaUnreviewed, approved by shop, rejected, or re-test requiredRecheck setup after nozzle/ceramic changes; redetermine focus after lens/laser replacementBM111 V1.0 §§5.1, 5.2, 6.3.2 for check triggers; shop controls approvalOEM statements apply to historical BM111 only; other machines use their own instructionsScoped OEM triggers; approval is the shop’s decision2026-11-02

Reference workflow

  1. Match the job, material, machine head, and quality requirement to a row.
  2. Confirm the source, review date, and confidence before copying the value into a quote worksheet.
  3. Use a measured result or current OEM record when the row is marked as required or unverified.